D-RG138 EC Gas Blower: Plastic Impeller, PWM Control and OEM Integration

  • Gas Boiler Blowers
  • Premix Combustion Systems
Posted by Ningbo E-POWER Energy Saving Technology Co.,Ltd On Nov 18 2026

The D-RG138 EC gas blower is designed for controlled combustion-air delivery in gas boilers, burner assemblies, and industrial heating equipment.

Manufactured by Ningbo E-POWER Energy Saving Technology Co., Ltd., this model combines an electronically commutated motor with a plastic impeller and centrifugal blower structure.

Its 300W input and adjustable-speed capability provide an option for OEM manufacturers requiring specific airflow and pressure performance.

D-RG138 EC gas blower with PWM speed control

D-RG138 Technical Specifications

The D-RG138 EC gas blower provides the following published specifications:

Parameter Specification
Model D-RG138
Rated Voltage 100–120 / 220–230 VAC
Frequency 50/60 Hz
Power Input 300W ±10%
Catalog Combustion Power 150 kW
Maximum Speed 6,500 RPM ±10%
Airflow 310 m³/h / 185 CFM
Maximum Static Pressure 5,000 Pa ±5%
Input Current 3.0 / 2.0 A
Net Weight 2 kg
Impeller Material Plastic

Maximum airflow and static pressure occur at different operating points. The 150 kW combustion-power figure is a catalog reference, not a guarantee of burner compatibility.

Plastic Impeller Design and Airflow Performance

The D-RG138 features a plastic impeller, distinguishing it from the D-RG138T metal impeller version.

Plastic and metal impellers have different mechanical and thermal characteristics. The appropriate design depends on operating conditions and equipment requirements.

The published airflow-pressure curve compares D-RG138 with D-RG138H, helping engineers evaluate their performance characteristics.

Actual selection should be based on the required system duty point rather than maximum ratings alone.

D-RG138-dimensions.webp

PWM Speed Control and Installation

The D-RG138 EC gas blower supports adjustable operation through compatible PWM control.

According to the published wiring diagram, startup requires a duty cycle above 5%. Full-speed operation is specified at 100% duty cycle or without a PWM connection.

OEM engineers should verify wiring, connectors, and control compatibility before integration.

Installation guidance specifies a horizontal shaft or motor-mounted-on-top arrangement.

Mounting dimensions and electrical connections should be confirmed against the approved engineering drawings.

Common Applications

The D-RG138 can be evaluated for several combustion-air applications.

Gas Boilers: Airflow supply for compatible residential and commercial heating equipment.

Industrial Heating: Controlled air delivery for industrial combustion systems.

Gas Burner Systems: Integration with suitable burner controllers, gas valves, and mixing components.

Final suitability requires complete-system performance and safety validation.

Explore E-POWER Gas Burner Systems Solutions.

D-RG138-curve.webp

OEM Customization and Quality Assurance

E-POWER provides motor engineering, electronic control development, blower manufacturing, and performance testing.

OEM support includes airflow matching, electrical-interface evaluation, sample testing, and customization assessment.

Quality-control activities include incoming inspection, motor testing, airflow verification, and final product inspection.

For technical evaluation, buyers should provide airflow, static pressure, voltage, installation drawings, control specifications, and estimated purchasing quantities.

Review the D-RG138 Product Details or contact E-POWER for technical documentation and OEM quotations.

Conclusion

The D-RG138 EC gas blower combines a 300W motor input, plastic impeller, and PWM-controlled centrifugal airflow for heating and combustion equipment.

Its published specifications help OEM engineers evaluate performance, installation compatibility, and purchasing requirements.

Contact E-POWER to discuss D-RG138 specifications, customization options, and bulk purchasing requirements.

Featured Blogs
D-RG138 EC Gas Blower: Plastic Impeller, PWM Control and OEM Integration

D-RG138 EC Gas Blower: Plastic Impeller, PWM Control and OEM Integration

The D-RG138 EC gas blower combines a 300W motor input with a plastic impeller for controlled combustion-air delivery in gas boilers and industrial heating equipment. This guide introduces its technical specifications, airflow-pressure performance, PWM speed control, installation requirements, and OEM integration considerations.

D-RG148L EC Gas Blower: 130W PWM Control and OEM Heating Applications

D-RG148L EC Gas Blower: 130W PWM Control and OEM Heating Applications

The D-RG148L EC gas blower combines a 130W motor input with electronically controlled airflow for heating and combustion equipment. This guide introduces its technical specifications, airflow-pressure performance, PWM speed control, installation dimensions, and OEM integration requirements.

D-RG148 EC Gas Blower: 210W Performance, PWM Control and OEM Boiler Integration

D-RG148 EC Gas Blower: 210W Performance, PWM Control and OEM Boiler Integration

The D-RG148 EC gas blower combines a 210W motor input with electronically controlled airflow for gas boilers and industrial heating equipment. This guide covers its technical specifications, PWM speed control, airflow-pressure performance, installation dimensions, and OEM integration requirements.

D-RG148T EC Gas Blower: 200W Metal Impeller for OEM Burner Systems

D-RG148T EC Gas Blower: 200W Metal Impeller for OEM Burner Systems

The D-RG148T EC gas blower combines a 200W motor input with a metal impeller for controlled combustion-air delivery. This guide introduces its technical specifications, airflow-pressure performance, installation requirements, and OEM applications in gas boilers and industrial burner systems.

D-RG148LT EC Gas Blower: 130W Metal Impeller for OEM Heating Equipment

D-RG148LT EC Gas Blower: 130W Metal Impeller for OEM Heating Equipment

The D-RG148LT EC gas blower combines a 130W motor input with a metal impeller for controlled combustion-air delivery. This guide covers its technical specifications, airflow-pressure characteristics, mounting requirements, and OEM applications in gas boilers and industrial heating equipment.

D-RG138T EC Gas Blower: Metal Impeller Performance for OEM Combustion Systems

D-RG138T EC Gas Blower: Metal Impeller Performance for OEM Combustion Systems

The D-RG138T EC gas blower features a metal impeller and electronically commutated motor for controlled airflow in gas boilers and industrial combustion equipment. This guide covers its technical specifications, airflow-pressure performance, installation requirements, and OEM integration considerations.