D-RG148T EC Gas Blower: 200W Metal Impeller for OEM Burner Systems

  • Gas Boiler Blowers
  • Premix Combustion Systems
Posted by Ningbo E-POWER Energy Saving Technology Co.,Ltd On Nov 12 2026

The D-RG148T EC gas blower is designed for controlled combustion-air delivery in gas boilers, industrial burners, and heating equipment.

Manufactured by Ningbo E-POWER Energy Saving Technology Co., Ltd., this model combines a 200W electronically commutated motor with a metal impeller and centrifugal blower structure.

Its performance characteristics provide OEM manufacturers with another option within the D-RG148 product family.

D-RG148T EC gas blower for OEM heating systems

What Makes the D-RG148T Different?

The D-RG148T features a metal impeller, 200W power input, and a published maximum static pressure of 4,100 Pa.

Compared with the D-RG148LT, which has a 130W input and 190 m³/h airflow rating, the D-RG148T offers a different performance configuration.

Metal impeller construction provides specific mechanical characteristics, while EC motor technology supports adjustable blower operation through compatible electronic controls.

Final suitability depends on the equipment's actual airflow-pressure requirements.

D-RG148T Technical Specifications

The D-RG148T EC gas blower provides the following published specifications:

Parameter Specification
Model D-RG148T
Rated Voltage 110 / 220 V
Frequency 50/60 Hz
Power Input 200 W
Catalog Combustion Power 100 kW
Maximum Speed 6,800 RPM
Airflow 220 m³/h / 130 CFM
Maximum Static Pressure 4,100 Pa
Input Current 1.7 A
Net Weight 1.9 kg
Impeller Material Metal

Maximum airflow and static pressure represent different operating conditions. The published 200–277 V operating range should be clarified against the rated-voltage information before ordering.

The 100 kW combustion-power figure is a catalog reference, not a guarantee of compatibility with every 100 kW burner.

Airflow Performance and Installation

The D-RG148T centrifugal blower is designed to deliver airflow against combustion-system resistance.

OEM engineers should compare its performance curve with the required operating points of the burner, heat exchanger, and connected air passages.

The manufacturer specifies installation with the shaft horizontal or the motor mounted on top.

Electrical connections, control interfaces, and mounting dimensions must be verified before integration.

Common Applications

The D-RG148T EC gas blower can be evaluated for several applications.

Gas Boilers: Combustion-air delivery for compatible residential and commercial heating systems.

Industrial Heating: Airflow supply for equipment requiring controlled pressure performance.

Gas Burner Systems: Integration with suitable gas valves, mixing components, and electronic burner controls.

Complete-system validation is required to confirm compatibility and safety.

Explore E-POWER Gas Burner Systems Solutions.

OEM Customization and Quality Assurance

E-POWER provides motor engineering, electronic control development, blower manufacturing, and performance testing capabilities.

OEM support includes airflow matching, electrical-interface assessment, installation review, and customization evaluation.

Quality-control activities include incoming inspection, motor testing, airflow verification, and final product inspection.

For technical evaluation, buyers should provide required airflow, static pressure, voltage, installation drawings, and estimated purchasing volume.

Review the D-RG148T Product Details or contact E-POWER for OEM quotations.

Conclusion

The D-RG148T EC gas blower combines a 200W motor input, metal impeller design, and centrifugal airflow performance for heating and combustion equipment.

Its specifications help OEM engineers assess system compatibility, installation requirements, and purchasing needs.

Contact E-POWER to discuss D-RG148T specifications, customization options, and bulk purchasing requirements.

Featured Blogs
D-RG148T EC Gas Blower: 200W Metal Impeller for OEM Burner Systems

D-RG148T EC Gas Blower: 200W Metal Impeller for OEM Burner Systems

The D-RG148T EC gas blower combines a 200W motor input with a metal impeller for controlled combustion-air delivery. This guide introduces its technical specifications, airflow-pressure performance, installation requirements, and OEM applications in gas boilers and industrial burner systems.

D-RG148LT EC Gas Blower: 130W Metal Impeller for OEM Heating Equipment

D-RG148LT EC Gas Blower: 130W Metal Impeller for OEM Heating Equipment

The D-RG148LT EC gas blower combines a 130W motor input with a metal impeller for controlled combustion-air delivery. This guide covers its technical specifications, airflow-pressure characteristics, mounting requirements, and OEM applications in gas boilers and industrial heating equipment.

D-RG138T EC Gas Blower: Metal Impeller Performance for OEM Combustion Systems

D-RG138T EC Gas Blower: Metal Impeller Performance for OEM Combustion Systems

The D-RG138T EC gas blower features a metal impeller and electronically commutated motor for controlled airflow in gas boilers and industrial combustion equipment. This guide covers its technical specifications, airflow-pressure performance, installation requirements, and OEM integration considerations.

D-RG118C EC Gas Blower: External Control Board and OEM Integration Guide

D-RG118C EC Gas Blower: External Control Board and OEM Integration Guide

The D-RG118C EC gas blower features a separate external control board for combustion-air applications in gas boilers and industrial heating equipment. This guide introduces its technical specifications, control-board configuration, installation requirements, and OEM integration considerations.

D-RG148HT EC Gas Blower: Metal Impeller Design, Specifications and OEM Applications

D-RG148HT EC Gas Blower: Metal Impeller Design, Specifications and OEM Applications

The D-RG148HT EC gas blower features a metal impeller and electronically commutated motor technology for controlled airflow in heating and combustion equipment. This guide introduces its technical specifications, design characteristics, installation requirements, and OEM integration considerations.

D-RG148H EC Gas Blower: Features, Specifications and OEM Heating Applications

D-RG148H EC Gas Blower: Features, Specifications and OEM Heating Applications

The D-RG148H EC gas blower provides controlled combustion airflow for gas boilers, heating equipment, and industrial burner systems. This guide introduces its technical specifications, airflow-pressure performance, PWM speed control, installation requirements, and OEM integration considerations.