D-RG148L EC Gas Blower: 130W PWM Control and OEM Heating Applications

  • Gas Boiler Blowers
  • Premix Combustion Systems
Posted by Ningbo E-POWER Energy Saving Technology Co.,Ltd On Nov 16 2026

The D-RG148L EC gas blower is designed for controlled combustion-air delivery in gas boilers, burner systems, and industrial heating equipment.

Manufactured by Ningbo E-POWER Energy Saving Technology Co., Ltd., this model combines electronically commutated motor technology with a compact centrifugal blower design.

With a 130W rated power input and PWM speed-control capability, the D-RG148L provides an option for OEM manufacturers requiring adjustable airflow and compatible electrical integration.

D-RG148L EC gas blower with PWM speed control

D-RG148L Technical Specifications

The D-RG148L EC gas blower offers the following published specifications:

Parameter Specification
Model D-RG148L
Rated Voltage 100–120 / 220–230 VAC
Frequency 50/60 Hz
Power Input 130W ±10%
Catalog Combustion Power 80 kW
Maximum Speed 5,500 RPM ±10%
Airflow 190 m³/h / 110 CFM
Maximum Static Pressure 3,500 Pa ±5%
Input Current 1.7 / 0.9 A
Net Weight 1.9 kg

Maximum airflow and static pressure occur at different operating points. The 80 kW combustion-power rating is a catalog reference, not a guarantee of burner compatibility.

These specifications help OEM engineers assess electrical requirements and preliminary airflow suitability.

Airflow Performance and PWM Speed Control

The D-RG148L EC gas blower supports adjustable operation through compatible PWM control.

According to the manufacturer's documentation, startup requires a PWM duty cycle above 5%. Full-speed operation is specified at 100% duty cycle or without a PWM connection.

Its published performance curve compares the D-RG148L with the higher-output D-RG148 and D-RG148H models.

OEM engineers should verify the actual airflow-pressure duty point, control signals, and connector configuration before equipment integration.

Dimensions and Installation Requirements

The D-RG148L has published dimensions of:

  • Width: 184.4 mm

  • Height: 190.7 mm

  • Depth: 145.2 mm

Its structure includes an outlet flange, mounting holes, power connector, and speed-control connector.

Installation guidance specifies a horizontal shaft or motor-mounted-on-top arrangement.

Correct mounting and electrical connections are essential for reliable system integration.

Common Applications

The D-RG148L EC gas blower can be evaluated for several heating applications.

Gas Boilers: Controlled combustion-air supply for compatible residential and commercial boilers.

Industrial Heating: Airflow support for equipment requiring defined pressure characteristics.

Gas Burner Systems: Integration with suitable burner controllers, gas valves, and mixing components.

Actual suitability requires complete-system performance and safety validation.

Explore E-POWER Residential Heating Solutions.

OEM Customization and Quality Assurance

E-POWER provides motor engineering, electronic control development, blower manufacturing, and performance testing capabilities.

OEM support includes airflow matching, electrical-interface evaluation, sample testing, and customization assessment.

Quality-control activities include incoming inspection, motor performance testing, airflow verification, and final product inspection.

For technical evaluation, buyers should provide airflow requirements, static pressure, voltage, installation drawings, control specifications, and estimated purchasing quantities.

Review the D-RG148L Product Details or contact E-POWER for technical documentation and OEM quotations.

Conclusion

The D-RG148L EC gas blower combines a 130W motor input, PWM speed control, and centrifugal airflow performance for heating and combustion equipment.

Its specifications help OEM engineers evaluate system requirements, electrical compatibility, and installation conditions.

Contact E-POWER to discuss D-RG148L technical specifications, customization options, and bulk purchasing requirements.

Featured Blogs
D-RG148L EC Gas Blower: 130W PWM Control and OEM Heating Applications

D-RG148L EC Gas Blower: 130W PWM Control and OEM Heating Applications

The D-RG148L EC gas blower combines a 130W motor input with electronically controlled airflow for heating and combustion equipment. This guide introduces its technical specifications, airflow-pressure performance, PWM speed control, installation dimensions, and OEM integration requirements.

D-RG148 EC Gas Blower: 210W Performance, PWM Control and OEM Boiler Integration

D-RG148 EC Gas Blower: 210W Performance, PWM Control and OEM Boiler Integration

The D-RG148 EC gas blower combines a 210W motor input with electronically controlled airflow for gas boilers and industrial heating equipment. This guide covers its technical specifications, PWM speed control, airflow-pressure performance, installation dimensions, and OEM integration requirements.

D-RG148T EC Gas Blower: 200W Metal Impeller for OEM Burner Systems

D-RG148T EC Gas Blower: 200W Metal Impeller for OEM Burner Systems

The D-RG148T EC gas blower combines a 200W motor input with a metal impeller for controlled combustion-air delivery. This guide introduces its technical specifications, airflow-pressure performance, installation requirements, and OEM applications in gas boilers and industrial burner systems.

D-RG148LT EC Gas Blower: 130W Metal Impeller for OEM Heating Equipment

D-RG148LT EC Gas Blower: 130W Metal Impeller for OEM Heating Equipment

The D-RG148LT EC gas blower combines a 130W motor input with a metal impeller for controlled combustion-air delivery. This guide covers its technical specifications, airflow-pressure characteristics, mounting requirements, and OEM applications in gas boilers and industrial heating equipment.

D-RG138T EC Gas Blower: Metal Impeller Performance for OEM Combustion Systems

D-RG138T EC Gas Blower: Metal Impeller Performance for OEM Combustion Systems

The D-RG138T EC gas blower features a metal impeller and electronically commutated motor for controlled airflow in gas boilers and industrial combustion equipment. This guide covers its technical specifications, airflow-pressure performance, installation requirements, and OEM integration considerations.

D-RG118C EC Gas Blower: External Control Board and OEM Integration Guide

D-RG118C EC Gas Blower: External Control Board and OEM Integration Guide

The D-RG118C EC gas blower features a separate external control board for combustion-air applications in gas boilers and industrial heating equipment. This guide introduces its technical specifications, control-board configuration, installation requirements, and OEM integration considerations.